  "generated_at": "2026-07-04T00:53:32+00:00",
  "model": "studio",
  "site": "severe",
  "method": "CalculiX S3 shell *BUCKLE on corner-network mid-surface",
  "mesh": {
    "nodes": 99503,
    "elements": 198656,
    "description": "faceted, target 50 mm, door-frame members at t = 98.0 mm, wood (6144 elements)",
    "target_size_mm": 50.0,
    "clamped_nodes": 4027
  },
  "reference_load": "pressure-only",
  "n_modes_requested": 6,
  "buckling_fos": 3.0,
  "cases": [
    {
      "case": "snow_balanced",
      "ok": true,
      "reference_pressure_Pa_outward": -3351.621,
      "buckling_factors": [
        4.498474,
        5.088103,
        5.215804,
        5.325933,
        5.562337,
        5.926845
      ],
      "mode1_blf": 4.498474,
      "required_fos": 3.0,
      "passes": true
    },
    {
      "case": "wind_uplift_main",
      "ok": true,
      "reference_pressure_Pa_outward": 3328.7612835234977,
      "buckling_factors": [
        4.281346,
        7.013671,
        7.222377,
        8.009441,
        9.139954,
        10.87689
      ],
      "mode1_blf": 4.281346,
      "required_fos": 3.0,
      "passes": true
    }
  ]
}