=== Step C: drilling-factor sweep on in-house DKT (site=baseline (typical CONUS)) === building corner network (70 panels, dedup_tol=300.0 mm)... 89 unique mid-plane corners (3.15 panels per corner). subdivision depth = 3 (mean edge 973 mm; target 200.0 mm; 4^d sub-triangles per base triangle) mid-surface mesh built: 4639 nodes, 8960 triangles (128 per panel). boundary nodes (y < 200 mm): 338 wrote VTU -> reports/full_dome_midsurface.vtu Mesh: 4639 nodes / 8960 tris Load: wind_cc_peak p = -3831 Pa (p_outward = 0.00383 MPa) Reference solver outputs (from prior runs): OpenSees ShellDKGT u_max=52.42 mm sigma_b=1.7450 MPa CalculiX S3 u_max=12.80 mm (membrane VM=0.385 MPa) In-house default drilling_factor = 1e-2 (current) drilling_factor u_max [mm] sigma_b_max [MPa] sigma_m_max VM_max ratio_u_to_OPS ratio_u_to_CCX 0.0e+00 30.330 23.9853 0.8402 27.1016 0.579 2.370 (6.1s) 1.0e-09 29.908 0.7763 0.8167 2.4094 0.571 2.337 (5.8s) 1.0e-07 29.908 0.7763 0.8167 2.4094 0.571 2.337 (5.6s) 1.0e-05 29.904 0.7761 0.8166 2.4091 0.570 2.336 (5.6s) 1.0e-03 29.790 0.7562 0.8146 2.3888 0.568 2.327 (5.7s) 1.0e-02 29.469 0.6450 0.8087 2.2597 0.562 2.302 (5.7s) 1.0e-01 28.321 0.6586 0.7769 1.8192 0.540 2.213 (5.8s) 1.0e+00 23.879 0.6291 0.6451 1.4018 0.456 1.866 (5.8s) Interpretation: - If u_max grows substantially as drilling_factor goes to 0, drilling stiffness is artificially reducing in-house deflection => OpenSees may have weaker / no drilling stabilisation. - If u_max is roughly constant across the sweep, drilling is NOT the cause of the OpenSees disagreement.